TOP > About SHY ZIP > PERFORMANCE DATA


 


 

 

Result: Permissible Tension Tmax
Tmax=Fmax / W=13.5EEg/cmEE/td>
Conditions: ·2SL-FCOAT PT16 Series SHY Slide-Fastener.
·33mm Guide-Rail System.
·NH6 PVC Inner-Rail

Rain Flow Rate: 4l/m² per minute;
Permissible
  Pressure:
250Pa∼750Pa(5.5kg/m²∼76.5kg/m²)
Permissible
  Wind Pressure:
±3,600Pa(±367kg/m²)
Test Fabrics: Mesh type fiberglass:SERGE(eqv.21136#)

Test: Weight-ball(1Kg) drops from different heights toward the screen.
Result: Center Fabrics is broken first before the Slide-Fastener structure.
Test Fabrics: Mesh type fiberglass:SERGE(eqv.21136#)

In general,all common-used fabrics can be applied for ordinary size internal window screen except very thin polyester fabrics.
Recommendation ·PVC Coating Fiberglass
(better welding performance and less stretching rate);
·Thicker fabrics is good for rolling performance.